OilLab 6000 – Leonardo Pensky Martens |
Download Brochure |
ASTM D93 procedures A, B, C
DIN EN 22719
IP 34
ISO 2719
CE marked
Subject
Flash Point on petroleum products, gas oils, fuel oils, lubrificants, biodiesel. Suitable for flash point detection on different substances, waste materials, solvents…
Measuring Pensky Martens Principle
The sample is heated and stirred at specified rates, using one of three defined procedures (A, B, or C). An ignition source is directed into the test cup at regular intervals with simultaneous interruption of the stirring, until a flash is detected.
Measuring Parameters
- Temperatures: in °C / °F
- Measuring range: 0°C … +420°C
- Resolution: 0.01 °C
- Accuracy: ± 0.1 °C
- Repeatability / Reproducibility: as per standards methods or better
Measuring Temperature Devices
- Sample temperature: PT100 sensor completely made in stainless steel resistant to corrosion and shock resistant
- Bath temperature: PT100 sensor
Pressure sensor
- Built-in sensor with automatic correction of results to a barometric pressure of 101.3 kPa automatically performed by the software at the end of analysis
Detection system
- A single multi-detector combines the ionization detector and the thermal detector
Double ignition system
- Gas
- Ectrical ignitor
Heater
- Electrical heating with heating rates as per procedures A, B, C
Stirrer
- An electric motor drives the stirring of the product
- Stirring speed as per selected procedures A, B, C
Cooling system
- Built-in forced air fan
Safety Devices
- Automatic diagnostic in case of breakage of the sample temperature probe and thermal sensors
- Automatic fire detection system
- Overheating protection with auto shut off during the test
- Gas valve for closing the gas supply (max 30 mBar), at the end of the test
Fire Extinguisher
- Automatic fire detection and extinguisher system
Software Features
- All analytical parameters recorded
- Customizable analysis parameters and methods
- Customizable results report
- Printable graphs and results
The software includes:
Analysis Menu
- Automatic execution of the analysis in accordance to the selected procedure (Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference as well as costumized procedures)
- Automatic handling of samples with unknown flash point
- Display in real time of all the analysis parameters and status
- Fields for introduction of operator and product name
- Expected flash point temperature programmable
- Audible alarm and displayed messages at the end of the analysis and in case of errors and/or malfunctions
- Configuration menu with up to 20 preset samples and expected flash point
- Automatic barometric correction of results
Diagnostic Menu
- Direct access to all analog, digital, inputs and outputs
- Selectable value displaying: °C / Volt
Calibration Menu
- Automatic calibration of each temperature probe
- Up to 100 calibration points (standard with 5 and dynamic with up to 100 points)
- Programmable calibration frequency with selectable validity period and notice/lock-down at expiration date
- Last calibration date referred to each single probe displayed and relevant data printable
- Display of calibration diagram
Data Utilities
- Archive viewer for files recall
- All analysis stored in Excel® compatible format
- LIMS compatible
Access via password to the following menu:
- calibration
- program settings
- selection ignitor type
Calibration:
- comparative with reference thermometer and barometer
- selection calibration due date
- automatic diagnostic in case of faulty of the temperature and thermal sensors
Analysis storage:
- storage capacity for more than 65.000 analysis
- export of test results files in the most common formats Excel and PDF
- Lin-Tech algorithm temperature ramp and auto-adapt for any type of sample
- Double Flash detection (by thermal sensor and ionization ring simultaneous)
- Rapid test selection between electrical ignitor and gas ignitor
- Automatic barometric correction of the results via a built-in barometer
- LIMS communication capable
- Reading interval of PT100 sample from 0 to 450 °C with resolution 0.01 °C
- Reading interval of PT100 bath from 0 to 450 °C with resolution 0.01 °C
- Double ignition system: gas and / or electrical ignitor
- Fully automatic arm that can be brought into three positions: cleaning, testing and idling time
Integrated Touch Screen Panel PC
- TFT/LCD 8.4″
- Resolution 1024 × 768, 16.2 M colours
- 2 × USB ports for connection to an external printer
- 1 × ethernet port for LAN and LIMS network
Electrical Supply
- 220V ± 15% / 50 to 60 Hz
- 115V ± 15% / 60 Hz
Ambient Temperature
- Max 35°C
- H.R. 80%
Dimensions
- width 37 cm
- depth 52 cm
- height 32 cm
Weight
- 30 Kg
Accessories / Spare Parts
- LAB-6000/05-23: heater collar
- LAB-6000/06-21: gas valve
- LAB-6000/07-01: electrical ignitor
- LAB-6000/07-03: micro switch
- LAB-6000/07-04: handle
- LAB-6000/07-05: gas ignitor
- LAB-6000/08-12: PT100 product
- LAB-6000/08-13: detection / ionisation cable
- LAB-6000/08-14: PT100 Bath
- LAB-6000/09-04: gas reducer
- LAB-6000/09-05: calibrated brass crucible
- LAB-6000/10-04: PCB fuses, box of 10
- LAB-6000/11-02: stirrer belt
- LAB-6000-118: fire extinguisher system
Calibration Tools
- OilLab 80: calibration decade box – PT100 simulator
- OilLab 91: set of connectors and cables for OilLab 6000